Nagole, Hyderabad, Telangana
GST No. 36AAOCA4431C1ZY
Approx. Rs 59,600 / UnitGet Latest Price
Product Details:Parameter to be Monitored | Temperature |
Type of Data Logger | Digital Data Logger |
No. of Channels | Single Channel |
For Quoted Accuracy | 20 degreeC to 30 degreeC |
General Operation | 0 degreeC to 45 degreeC |
Relative Humidity | 5% to 80% RH |
Dimensions | 135 x 184 x 36 mm (5.31 x 7.24 x 1.41 in) |
Specifications:
ADC-20 | ADC-24 | |
Resolution | 20 bits | 24 bits |
Number of channels# | 4 differential / 8 single-ended | 8 differential / 16 single-ended |
Conversion time (per channel) | 660 ms, 340 ms, 180 ms, 100 ms, 60 ms | |
Voltage ranges | ±2500 mV ±1250 mV | ±2500 mV ±1250 mV ±625 mV ±312 mV ±156 mV ±78 mV ±39 mV |
Accuracy | 0.002 | 0.1% (±39 mV to 1250 mV range) 0.2% (±2500 mV range) |
Noise rejection | 120 dB typical at 50/60 Hz | |
Input impedance | Differential: 2 MΩ Single-ended: 1 MΩ | |
Common mode input range, channel to common | ±1.9 V (±39 mV to ±1250 mV ranges) ±3.0 V (±2500 mV range) | |
Common mode input range, common to earth ground | ±30 V | |
Common mode rejection ratio, channel to common | 95 dB (DC to 60 Hz) | |
Common mode rejection ratio, common to earth ground | > 125 dB (DC to 60 Hz) | |
Overvoltage protection | ±30 V | |
Digital I/O | none | 4 bidirectional (3.3 V CMOS) |
Reference output | +2.5 V ±2.5 mV @ 2 mA +5 V ±1.0 V @ 2 mA –5 V ±1.5 V @ 2 mA |
PC requirements | |
Minimum | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32-bit: 600 MB, 64-bit: 1.5 GB. Operating system: 32-bit or 64-bit edition of Microsoft Windows 7, Windows 8 or 10. Ports: USB 1.1. |
Recommended | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32-bit: 850 MB, 64-bit: 2 GB. Operating system: 32-bit or 64-bit edition of Microsoft Windows 7, 8 or 10. Ports: USB 1.1 or higher. |
Approx. Rs 44,000 / UnitGet Latest Price
Product Details:Operating Temperature | 0 to 50 degreeC |
Operating temperature for stated accuracy | 20 to 30 degreeC |
Operating Humidity | 5 to 80 %RH Non-condensing |
Storage Humidity | 5 to 95 %RH Non-condensing |
Water Resistance | Not water-resistant |
Dimensions | 201 x 104 x 34 mm (7.91 x 4.09 x 1.34 in) |
Specifications:
USB TC-08 Thermocouple Data Logger general specifications | |
Number of channels (single unit) | 8 |
Maximum number of channels (using up to 20 TC-08s) | 160 |
Conversion time | 100 ms per thermocouple channel + 100 ms for cold junction compensation (CJC can be disabled if all channels used as voltage inputs) |
Temperature accuracy | Sum of ±0.2% of reading and ±0.5 °C |
Voltage accuracy | Sum of ±0.2% of reading and ±10 µV |
Overvoltage protection | ±30 V |
Maximum common-mode voltage | ±7.5 V |
Input impedance | 2 MΩ |
Input range (voltage) | ±70 mV |
Resolution | 20 bits |
Noise-free resolution | 16.25 bits |
Thermocouple types supported | B, E, J, K, N, R, S, T |
Input connectors | Miniature thermocouple |
PC requirements | |
Minimum | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB. Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7, Windows 8 (not Windows RT) or Windows 10. Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac). Ports: USB 1.1 port. |
Recommended | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32–bit: 850 MB, 64–bit: 2 GB. Operating system: 32– or 64–bit edition of Microsoft Windows 7, Windows 8 (not Windows RT) or Windows 10. Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac). Ports: USB 1.1 or higher. |
Additional Information:
Approx. Rs 3,500 / UnitGet Latest Price
Product Details:Bandwidth | 100 kHz |
Resolution | 8 bits |
Input Characteristics | 1 M Omega |
Input Type | Single-ended, BNC Connector |
Input Coupling | DC |
Timebases | 10 us/div to 5000 s/div |
Specifications:
Built-in sensors/outputs | |||
Channel | Range | Resolution | Accuracy |
Sound waveform | ±100 | ±0.2 | not calibrated |
Sound level | 55 to 100 dBA | 1 dBA | 5 dBA |
Temperature | -10 to +70 °C | 0.1 °C @ 25 °C | 2 °C @ 25 °C |
Light | 0 to 100 | 0.1 | not calibrated |
RGB LED | 16.7 million colours | 8 bit x 3 | not applicable |
Analog inputs | ||||
Type | Connector | Range | Resolution | Accuracy |
pH | BNC | 0 to 14 pH | 0.02 pH | Sensor calibration dependent |
Redox/ORP | BNC (shared with pH) | ±2000 mV @ 1012 Ω | 1.2 mV | Sensor calibration dependent |
Resistance | Screw terminal | 0 to 1 MΩ | 250 Ω @ 10 k | 0.05 |
External sensors | 3 x FCC68 4/4 | Measure 0 to 2.5 V (Also supply power to external sensors and identify sensor type via ID resistor.) | 1 mV | 0.01 |
Additional Information:
Approx. Rs 4,000 / UnitGet Latest Price
Product Details:Number of Channels | 3 |
Range (voltage input) | 0 to 1 V AC RMS |
RMS Noise | 60 uV |
Resolution | 24 bit |
Conversion Time per Enabled Channel | 720 ms |
Voltage Input | 1 V RMS, 20 Hz to 1 kHz |
Input Connectors | 4 mm sockets |
Input Impedance | Greater than1 M Omega, AC coupled |
PC requirements | |
Minimum | Processor: 1 GHz Memory: 512 MiB Free disk space: 32-bit: 600 MB, 64-bit: 1.5 GB Operating system: 32- or 64-bit edition of Microsoft Windows XP (SP3), Vista, Windows 7, Windows 8.1 (not Windows RT) or Windows 10 Ports: USB 1.1 port or Ethernet. |
Recommended | Processor: 1 GHz Memory: 512 MiB Free disk space: 32-bit: 850 MB, 64-bit: 2 GB Operating system: 32- or 64-bit edition of Microsoft Windows 7, Windows 8.1 (not Windows RT) or Windows 10 Ports: USB 1.1 (or higher), or Ethernet. |
Environmental | |
Operating environment Temperature range Humidity range | 0 °C to 50 °C (20 °C to 28 °C for stated accuracy) 20% to 80% RH, non-condensing |
Storage environment Temperature range Humidity range | –20 °C to +60 °C 5% to 95% RH, non-condensing |
Software | ||
PicoLog for Windows | PicoLog data acquisition software can collect up to 1 million samples. Features include: Multiple views — view data as a graph, spreadsheet or text Parameter scaling — convert raw data into standard engineering units Math functions — use mathematical equations to calculate additional parameters Alarm limits — program an alert if a parameter goes out of a specified range IP networking — transfer measurements via a LAN or over the internet Operating systems supported — Microsoft Windows XP (SP3) to Windows 10. Not Windows RT. | |
PicoLog languages | Full support for — English, Français, Deutsch Menus and dialogs only for — Italiano, Español, Svenska | |
Software Development Kit | Includes example code. | |
Optional free software | Drivers for Linux and OS X. |
Additional Information:
Approx. Rs 4,000 / UnitGet Latest Price
Product Details:For Quoted Accuracy | 20 degree C to 50 degree C |
General Operation | 0 degree C to 70 degree C |
Relative Humidity | 5% to 80% RH |
Dimensions | 45 x 100 x 140 mm (1.77 x 3.94 x 5.51 in) |
Weight | Less Than 200 g (7.05 oz) |
Inputs | ||
Model | PicoLog 1012 | PicoLog 1216 |
Maximum sampling rate Continuous streaming Real-time continuous Block mode#1 | 1 kS/s per channel in PicoLog, 100 kS/s shared by all channels using the supplied SDK 1 kS/s or greater 1 MS/s single-channel | |
Buffer memory | 8000 samples, shared by all channels | |
Analog inputs | 12#2 | 16#2 |
Analog bandwidth (–3 dB) | DC to 70 kHz | |
Input type | Single-ended, unipolar | |
Input voltage range | 0 to +2.5 V | |
Linearity (at 25 °C) | 1 LSB | |
Resolution | 10 bits | 12 bits |
Accuracy | 0.01 | 0.005 |
Overvoltage protection | ±30 V to ground | |
Input coupling | DC | |
Input impedance | 1 MΩ |
Outputs | ||
Digital output (D0…D3) | 2 | 4#2 |
Digital outputs (PWM) period duty cycle | None | 1 100 µs to 1800 µs Adjustable from 0% to 100% in 1% steps |
Digital outputs (all) the logic low voltage the logic high voltage current limit | 100 mV (typical) 3.3 V 1 kΩ resistors in series with outputs | |
Power output for sensors | 2.5 V @ 10 mA, current-limited |
Approx. Rs 59,600 / UnitGet Latest Price
Product Details:Dimensions | 184 x 135 x 36 mm (approx 5.31 x 7.24 x 1.42 in) |
Weight | 350 g (approx 12.3 oz) |
Software Development Kit | Includes example code. |
Optional Free Software | Drivers for Linux and OS X. |
Accuracy and resolution:
Although accurate temperature sensors are widely available, it has been difficult to take advantage of them due to errors caused by the measuring device. Your PT-104 however, is inherently accurate due to its innovative design. Rather than relying on voltage references (which tend to be temperature sensitive) it uses ‘reference’ resistors which are extremely stable (low temperature coefficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly recalibration is recommended). A high-performance 24-bit ADC is used to achieve the 0.001 °C resolution.
Specifications:
Input/output | |||
Type | Temperature | Resistance | Voltage |
Sensor | PT100, PT1000 | n/a | n/a |
Range | –200 to +800 °C | 0 to 375 Ω 0 to 10 kΩ | 0 to 115 mV 0 to 2.5 V |
Accuracy (at 23 ±2 °C) | 0.015 °C + 0.01% of reading | 20 ppm at 100 Ω | 0.004 |
Temperature coefficient | 5 ppm/°C | 5 ppm/°C | 100 ppm/°C |
RMS noise with filter | 0.01 °C | 10 ppm | 10 ppm |
Resolution | 0.001 °C | 1 µΩ | 0.156 µV |
Overload protection | ±30 V | ||
Number of inputs | 4 | ||
Converter resolution | 24 bits | ||
Conversion time | 720 ms per channel | ||
Input connectors | 4-pin mini-DIN | ||
Input impedance | >1 MΩ | ||
Output connectors | USB and Ethernet |
Additional Information:
Approx. Rs 4,000 / UnitGet Latest Price
Product Details:Dimensions (probe head) | 68 x 19 x 11 mm |
Nominal Probe tip Pitch | 5 mm |
Weight | 5 g |
Environment | |
Operating temperature range | 0 to 50°C |
Storage temperature range | –20 to 70°C |
Temperature range for stated specifications | 15 to 40°C |
Operating humidity range | 5% to 80% RH non-condensing |
Storage humidity range | 5% to 95% RH non-condensing |
Altitude range | up to 2000 m |
Pollution degree | 2 |
Safety approvals | EN61010-031:2002+A1 2008 safety requirements for hand-held probe assemblies for electrical measurement and test |
EMC approvals | Not applicable |
Environmental approvals | 2012/19/EU - Waste Electrical and Electronic Equipment 2011/65/EU - Restriction of use of certain Hazardous Substances in Electrical and Electronic Equipment |
General | |
Output connector (probe head) | SMA(f |
Supplied cable | 60 cm SMA(m-m) precision unsleeved high-flex 085 microwave coaxial cable (unsleeved and 30 cm options also available) |
Supplied accessories | Pack of replacement probe tips; two coils of solder-in gold-plated wire; SMA-to-BNC adaptor (with RF, microwave and pulse models only) |
Explore More Products
4.0/5
Rated by 7 Users
© Ajitek Tech Solutions Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited